    Small Volume Rack Mounted Load Bank Overheat Protection For Data Center

    Ask Lasest Price
    Brand Name : Kaixiang
    Model Number : AC220V-6kW
    Certification : ISO9001
    Price : negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 100Sets/Month
    Delivery Time : Within 20 days
    • Product Details
    • Company Profile

    Small Volume Rack Mounted Load Bank Overheat Protection For Data Center

    AC220V-6kW Rack Mounted Load Bank With Frequency 50HZ And Best Sales

    Introduction

    This unit specially designed for data center, it’s safe, reliable, small volume and can simulate the on-site server load.

    Constant power. This unit is self-developed electric power load simulation equipment.

    The diagram in the agreement is only for reference, specific please in kind prevail.

    Application

    AC220V-6kW Rack Mounted Load Bank With Frequency 50HZ

    When building a data center, any unexpected glitch during commissioning can cause serious project delays, wasted productivity, and significant budget overruns. So integrating rack mounted load banks into the design phase can help our data center clients keep projects on budget and on time.

    Technical specification


    System Parameter
    Rating voltage/frequencySingle phase 220VAC/50Hz
    Max Load PowerResisitive Power: 6kW
    Load ResolutionResistive Load: 3 steps. A circuit 2kW; B circuit 2kW; C circuit 2kW;
    Power Factor1
    Load Tolerance+(0-10%)
    Insulation GradeGrade F
    Way of WorkingContinuous Working
    CoolingForced air cooling, intake air in front and exhaust cooling in back
    Case ColorBlack
    Case DimensionAbout 440mm*440mm*222mm(L×W×H)
    WeightAbout 18kgs
    Working Environment Parameter
    Ambient Temperature-10℃~+40℃
    Relative Humidity≤95%
    Altitude≤2500 meters
    Atmospheric Pressure86~106kPa
    Brands of Main Components
    Gear SwitchABB

    Main features
    The load bank is with 2 gear switches, can load/unload through 2 gear air switches combination, Max power is 6kW. Please connect A loop switch at first when operating, and must keep the A switch in the open state. If overheat alarm, please turn off the power switch and then check the equipment problem.

    (1) Load Test: User can load any power within rated power, and test the output capacity of under test power supply.

    (2) Control Mode: The laod bank is with 2 gear switches, can control loading/unloading by 2 ABB air switches.

    (3) Fan Power Supply: Fan is installed near the air outlet, and powered on A loop socket. Please give priority to the use A loop when using this load bank, the fan start after A loop is connected to power supply, then can load/unload through 2 gear air switches combination.

    (4) Temperature Protection: There will be sound and light alarm when the load bank temperature exceeds the safety threshold value.

    (5) Load bank Cable: The internal cable adopts multi core flame retardant flexible cord, and with glass fiber casing protection