Sign In | Join Free | My himfr.com
Home > Dummy Load Bank >

Grey / Blue 3546 KVA Dummy Load Bank Safety Monitor In High Performance

Hebei Kaixiang Electrical Technology Co., Ltd
Contact Now
    Buy cheap Grey / Blue 3546 KVA Dummy Load Bank Safety Monitor In High Performance from wholesalers
     
    Buy cheap Grey / Blue 3546 KVA Dummy Load Bank Safety Monitor In High Performance from wholesalers
    • Buy cheap Grey / Blue 3546 KVA Dummy Load Bank Safety Monitor In High Performance from wholesalers
    • Buy cheap Grey / Blue 3546 KVA Dummy Load Bank Safety Monitor In High Performance from wholesalers

    Grey / Blue 3546 KVA Dummy Load Bank Safety Monitor In High Performance

    Ask Lasest Price
    Brand Name : Kaixiang
    Model Number : AC480V-3546KVA
    Certification : ISO9001
    Price : negotiable
    Payment Terms : Western Union, L/C, T/T
    Supply Ability : 40Sets/Month
    Delivery Time : Within 30 working days
    • Product Details
    • Company Profile

    Grey / Blue 3546 KVA Dummy Load Bank Safety Monitor In High Performance

    AC480V-3546KVA Dummy Load Bank In High Performance And Resistive Inductive

    Introduction

    Triumph load can simulate the real working conditions and provides a rigorous test regime for power supplies from 1kW to 60MW. Resistive, inductive(reactive),capacitive or combined load banks can be customised for any application. They can be used for testing numerous sets in a workshop environment, or used for on-site commissioning, witness tests and proof trials.Tailor-made load banks can be supplied for most powers, voltages, frequencies and sizes. Multi-voltage load banks are also available for operation over a large voltage range. At the same time, It can operate in parallel with more than two units.

    Application

    AC480V-3546KVA Dummy Load Bank can be used in a wide variety of applications, such as

    Ups system testing,Battery system testing,Load optimization in prime power applications

    Factory testing of turbines,Factory testing of engine generator sets,To reduce wet stacking problems

    Periodic excercising of stand-by engine generator sets

    Technical specification


    System Parameter
    Rating voltage/frequency

    480V, 3 phase 3 wire, 60HZ

    208V, 3 phase 3 wire, 60HZ

    Max Load Power

    480V,3phase 3wire, 60HZ, star coupling “Y”

    Apparent Power: 3546KVA

    Resistive Load: 2836kW

    Inductive Load: 2128KVAR

    208V,3phase 3wire, 60HZ, delta coupling “△”

    Apparent Power: 2000KVA

    Resistive Load: 1600kW

    Inductive Load: 1200KVAR

    Load Resolution

    208V,3phase 3wire, 60HZ, delta coupling “△”

    Resistive load: 0.1,0.2,0.2,0.5,1,2,2,5,10,10,20,50,100,7*200kW

    Inductive load: 0.1,0.2,0.2,0.5,1,2,2,5,10,10,20,50,100,5*200kvar

    480V,3phase 3wire, 60HZ, star coupling “Y”

    Resistive load: 0.18,0.36,0.36,0.9,1.8,3.6,3.6,9,18,18,36,90,180,7*360kW

    Inductive load: 0.18,0.36,0.36,0.9,1.8,3.6,3.6,9,18,18,36,90,180,5*360kvar

    Power Factor0.8(lag)
    Load Tolerance (each step)±5%
    Load Tolerance (overall)±3%
    Fan &Control VoltageExternal AC 3 phase 4 line, 380V/50Hz
    Wire Connection

    Load bank input——Copper bar (star coupling ”Y”)

    Control power input——Connector-bar

    Communication InterfaceRS485,RS232
    InsulationF
    Max Protection GradeIP54
    Duty CycleContinuous
    CoolingForced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
    EnclosureContainer type,with a ladder, air inlet and outlet with mesh enclosure and protection door
    Internal LightingAdequate internal lighting will be provided
    TransportationHoisting, there are lifting lug in top of casing
    ColorGrey RAL7035 or as required
    Dimensions6058mm×2438mm×2896mm(L×W×H)
    Operating Environment Parameter
    WorkplaceOutdoor
    Ambient Temperature-10℃~+50℃
    Relative Humidity≤95%
    Atmospheric Pressure86~106kPa
    Brands of Main Components
    ContactorSchneider
    FuseMiro
    PLCSiemens
    Alloy ResistorKaixiang
    Data Processing SoftwareKaixiang
    Main features
    Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.
    Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.

    Overvoltage Protection: the input load voltage is over the safe threshold value, system unload automatically and give an alarm.

    Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.

    Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.

    Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.

    Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.

    Overload protection with fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.

    Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.





    Quality Grey / Blue 3546 KVA Dummy Load Bank Safety Monitor In High Performance for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hebei Kaixiang Electrical Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)