Sign In | Join Free | My himfr.com
Home > Reactive Load Bank >

2000kva Diesel Generator Load Bank Testing Equipment Reactive Performance

Hebei Kaixiang Electrical Technology Co., Ltd
Contact Now
    Buy cheap 2000kva Diesel Generator Load Bank Testing Equipment Reactive Performance from wholesalers
     
    Buy cheap 2000kva Diesel Generator Load Bank Testing Equipment Reactive Performance from wholesalers
    • Buy cheap 2000kva Diesel Generator Load Bank Testing Equipment Reactive Performance from wholesalers
    • Buy cheap 2000kva Diesel Generator Load Bank Testing Equipment Reactive Performance from wholesalers

    2000kva Diesel Generator Load Bank Testing Equipment Reactive Performance

    Ask Lasest Price
    Brand Name : KaiXiang
    Model Number : AC400V-2000KVA
    Certification : ISO9001-2008
    Price : negotiable
    Payment Terms : Western Union, L/C, T/T
    Supply Ability : 30 Sets per Month
    Delivery Time : Within 50 working days
    • Product Details
    • Company Profile

    2000kva Diesel Generator Load Bank Testing Equipment Reactive Performance

    cabinet power banks 2000kva with reactive performance for kuwait testing equipment
    Introduction

    (1) According to the special requirements of users on site, in the agreement the technical standards of AC400V-2000KVA Resistive Inductive Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.

    (2) The system consists of 1 sets of 2000KVA Load Bank, The resistive power is 1600kW, the inductive power is 1200KVAR. The system is made up of two parts of measurement & control and load, mainly including the medium voltage dry type AC load bank, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote control box and PC software and so on.

    (3) This system, which is of independent research and development of electricity load test equipment by our technology, combining high voltage dry type load module with the automatic measurement and control module, with excellent insulation protection performance, it can detect generator output power and load capacity, full load and overload test.

    The system can be used with a computer to realize the intelligent control, automatically completing the special test to all electrical parameters of generating set and generating tables, graphs, and supporting the print, release from the cumbersome manual operation to provide scientific and efficient detection means for the large power high voltage generating sets.

    (4) All the schematic diagrams of this agreement are for reference only please in kind prevail

    Applications

    1 The system is a self-developed device used for electricity load testing by Kaixiang Technology. It perfectly combines the high voltage dry type load module and measurement and control module, precisely test output power and load performance of kinds of generator set.

    System mainly consists of resistance load, data collecting, control system, cooling device, etc. The system can test output power and load performance of generator sets.

    2 System can load power in rated range, measure generator steady-state 3 phase voltage, current, active power, power factor, frequency, and running time, and simulate the generator set real load working state. Power input using sectional type, energy dissipation type load, forced-air cooling, 3 phase fan decentralized supply air, air-flow is sufficient and low noise.

    3 System can work with PC software to realize intelligent operation, automatically finish the parameters testing, and create testing data table, curves and reports that can be printed, reduce a lot of manual operation.

    Technical Specifications


    System Parameter
    Rating voltage/frequency400V, 3 phase 4 wire 50Hz
    Max Load Power

    Apparent Power: 2000KVA

    Resistive Load: 1600kW

    Inductive Load: 1200KVAR

    Load Resolution

    Resistive Load: 16 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,200kW,200kW,200kW, 200kW,200kW,200kW,200kW

    Inductive Load: 14 steps

    1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR

    Power Factor0.8
    Load Tolerance (each step)±5%
    Load Tolerance (overall)±3%
    Fan &Control VoltageExternal 400V 3 phase 4 wire, 50Hz
    Wire Connection

    Load bank input——Copper bar (star coupling ”Y”)

    Control power input——Connector-bar

    Communication InterfaceRS485,RS232
    InsulationF
    Max Protection GradeIP54
    Duty CycleContinuous
    CoolingForced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
    EnclosureContainer type,with a ladder, air inlet and outlet with mesh enclosure and protection door
    Internal LightingAdequate internal lighting will be provided
    TransportationHoisting, there are lifting lug in top of casing
    ColorGrey RAL7035 or as required
    DimensionsAbout 6058mm×2350mm×2591mm(L×W×H)
    Operating Environment Parameter
    WorkplaceOutdoor
    Ambient Temperature-10℃~+50℃
    Relative Humidity≤95%
    Atmospheric Pressure86~106kPa
    Brands of Main Components
    ContactorSchneider
    FuseMiro
    PLCSiemens
    Alloy ResistorKaixiang
    Data Processing SoftwareKaixiang

    Main features

    New Load Bank Technology: using the international advanced AC load bank technology, overcome the old water bank defects, such as bear bumpy, unable to use when go to sea, realize Mooring Trial and Sea Trail, and simulate the real working condition of generator running.

    Mature Manufacturing Technology: load element using excellent anti-corrosion materials; waterproof insulation container packaging, suitable for adverse environment such as ocean. Internal layout is reasonable, air channel is clear, rapid heat emission, and satisfy continuous working need.

    High Power Load: high load power density, large capacity of single set, parallel running to finish super power testing, and realize tens of megawatts of power loading.

    Accurate Data: with high precision data collection module and measuring meter, related equipment has passed the certification by CMA (China Metrology Accreditation) qualification testing institution, and ensures the reliability of data.

    Flexible Control Mode: based on different using habit, several control modes as following can be choose, local panel operation, remote box controlling, and intelligent software.

    Intelligent Loading: after setting generator rated power in software, system realize rapid loading through preset proportion, automatically and continuously load multiple power value and common tests, like stepping, full load, and over load, so that improve working efficiency. High Efficiency Data Management: display real-time testing data, generate curves graphs automatically, also can put data into storage. According to generator set No. set up testing file, support to query at any time, and improve data management efficiency.

    Comprehensive Protection Function: multiple protection, like over temperature, smoke. When in danger, automatically terminate the test and give alarm to protect safety of personnel and equipment.

    Stable Running: with the latest generation control module as the core, a sharp rise in system response speed and anti-interference performance, avoid function failure in complex electrical environment, and ensure system running stably and reliably.



    Quality 2000kva Diesel Generator Load Bank Testing Equipment Reactive Performance for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hebei Kaixiang Electrical Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)