Sign In | Join Free | My himfr.com
Home > AC Load Bank >

Forced Air Cooling Variable Resistive Load Bank For Testing Generators UPS

Hebei Kaixiang Electrical Technology Co., Ltd
Contact Now
    Buy cheap Forced Air Cooling Variable Resistive Load Bank For Testing Generators UPS from wholesalers
     
    Buy cheap Forced Air Cooling Variable Resistive Load Bank For Testing Generators UPS from wholesalers
    • Buy cheap Forced Air Cooling Variable Resistive Load Bank For Testing Generators UPS from wholesalers
    • Buy cheap Forced Air Cooling Variable Resistive Load Bank For Testing Generators UPS from wholesalers

    Forced Air Cooling Variable Resistive Load Bank For Testing Generators UPS

    Ask Lasest Price
    Brand Name : KAIXIANG
    Model Number : AC400V-1500KW
    Certification : ISO9001
    Price : negotiable
    Payment Terms : L/C, D/A, D/P, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 20 SETS ONE MONTH
    Delivery Time : ONE MONTH AFTER GET DEPOSIT
    • Product Details
    • Company Profile

    Forced Air Cooling Variable Resistive Load Bank For Testing Generators UPS


    AC Variable Resistive 400v 1500kw Resistive Load Bank For Testing Generators UPS

    Product Description


    1. Load testing: load power that not beyond the rated power, testing and display stable state 3 phases voltage, current, active power, frequency, working time, etc of generator sets.

    2. Load/unload with one key:Either by manual control or software control, user can preset the power, then press load master button. Load bank loaded according to preset power to avoid load fluctuation during the power changing.

    3. Control Pattern: user can choose local control and intelligent control.

    4. Local Control: There is local control panel with several power steps; user can load/unload by button.


    Technical Parameters


    Rating Voltage/Frequency400VAC 50Hz/60Hz,3phase 4 wire
    Max Load PowerResistive Load: 1500kW
    Load Step

    Resistive Load:16 steps
    1,2,2,5,10,10,20,50,100,100,200,200,200,200,200,200kW

    Power Factor1
    Load Tolerance(each step)±5%
    Load Tolerance(overall)±3%
    Display Precision0.5 class
    Control Power SupplyExternal 415VAC, 3phase 4wire 50Hz
    Wire Connection

    Load Power Supply Input——Copper bar (star connection)
    Control power supply input——Connector bar

    Communication InterfaceRS232 and RS485
    Insulation ClassF
    Duty CycleContinuous
    CoolingForced air cooling, horizontal air inlet and air outlet
    TransportationHoisting, there are lifting lug in top of case and wheel castors on the bottom
    Chassis colorGray(RAL7035)
    Size

    Approximately 1900mm*2900mm*2100mm
    (Width *Length *Height)

    WeightApproximately 2000kg
    Ambient Temperature-10℃~+50℃
    Relative Humidity≤95%
    Altitude≤2500meters
    Atmospheric Pressure86~106kPa


    Product Advantage

    Communication type: through RS232, RS485

    Load mode: manual load or automatic load.

    Manual load: input power and power factor.

    Automatic load: User can set several periods of power and time, and in turn of 0%→25%→50%→75%→100%, etc preset order to make automatic load testing.


    Application

    UPS inspection and maintenance
    Ship battery charging/discharging system testing
    The acceptance of new system and testing of servicing equipment

    Generators installed in the field must be periodically tested and exercised to ensure that it will operate as intended when a power outage actually occurs. Service groups use load banks to apply a load that mimics the load of the facility the generator is protecting. Any problems with the generator can then be identified and rectified in a non-critical environment.



    Quality Forced Air Cooling Variable Resistive Load Bank For Testing Generators UPS for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hebei Kaixiang Electrical Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)