Sign In | Join Free | My himfr.com
Home > 3 Phase Load Bank >

2500 KW Power Diesel Generator Load Bank Testing Equipment 50hz Frequency

Hebei Kaixiang Electrical Technology Co., Ltd
Contact Now
    Buy cheap 2500 KW Power Diesel Generator Load Bank Testing Equipment 50hz Frequency from wholesalers
     
    Buy cheap 2500 KW Power Diesel Generator Load Bank Testing Equipment 50hz Frequency from wholesalers
    • Buy cheap 2500 KW Power Diesel Generator Load Bank Testing Equipment 50hz Frequency from wholesalers
    • Buy cheap 2500 KW Power Diesel Generator Load Bank Testing Equipment 50hz Frequency from wholesalers

    2500 KW Power Diesel Generator Load Bank Testing Equipment 50hz Frequency

    Ask Lasest Price
    Brand Name : Kaixiang
    Model Number : AC425-2500kW
    Certification : ISO9001
    Price : negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 90 Sets per Month
    Delivery Time : Within 30 working days
    • Product Details
    • Company Profile

    2500 KW Power Diesel Generator Load Bank Testing Equipment 50hz Frequency

    westerbeke 2500 KW testing equipment for generator UPS

    Product description

    (1) According to the special requirements of users on site, in the agreement the technical

    standards of AC425-2500kW Intelligent Load Bank(hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.

    (2) The system consists of 1 sets of 2500kW load bank. The resistive power is 2500kW. The System is made up of two parts of measurement and control and load, mainly including the outdoor type dry load, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote controller and PC software and so on.

    Technical Parameter

    System Parameter
    Rating voltage/frequencyAC 3 phase 4 line, 425V/50Hz
    Max Load PowerResistive Load: 2500kW
    Load Resolution

    Resistive Load: 21 steps,

    1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,100kW,200kW,

    200kW, 200kW, 200kW, 200kW,200kW, 200kW, 200kW, 200kW, 200kW, 200kW

    Power Factor1
    Load Tolerance (each step)±5%
    Load Tolerance (overall)±3%
    Fan &Control VoltageExternal AC 3 phase 4 line,425V/50Hz
    Wire Connection

    Load bank input——Copper bar (star coupling ”Y”)

    Control power input——Connector-bar

    Communication InterfaceRS485,RS232
    InsulationF
    Max Protection GradeIP54
    Duty CycleContinuous
    CoolingForced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
    EnclosureContainer type,with a ladder, air inlet and outlet with mesh enclosure and protection door
    Internal LightingAdequate internal lighting will be provided
    TransportationHoisting, there are lifting lug in top of casing
    ColorGrey RAL7035 or as required
    DimensionsAbout 6058mm×2350mm×2591mm(L×W×H)
    Operating Environment Parameter
    Ambient Temperature-10℃~+50℃
    Relative Humidity≤95%
    Atmospheric Pressure86~106kPa
    Brands of Main Components
    ContactorSchneider
    FuseMiro
    PLCSiemens
    Alloy Resistor(self-developing)
    Data Processing Software(self-developing)
    Main features

    Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.

    Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.

    Overload protection with fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.

    Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.

    Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.

    Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.

    Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.

    Application

    Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
    Factory testing for generator, static voltage characteristic test, speed characteristic test;
    Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test



    Quality 2500 KW Power Diesel Generator Load Bank Testing Equipment 50hz Frequency for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hebei Kaixiang Electrical Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)