    Brand Name : Kaixiang
    Model Number : AC440V-4375kVA
    Certification : ISO9001
    Price : negotiable
    Supply Ability : 90 Sets / Month
    Delivery Time : Within 30 working days
    • Product Details
    • Company Profile

    440 V 3 Phase 4 Wire Reactive Load Bank Constant Power With Dry Load Module

    AC440V-4375kVA 3 Phase Load Bank With Best Sales And High Performance

    Introduction

    AC440-4375KVA RL Load Bank.The system consist of dry load module and auto control module, test load and output power of generators, the test including setting, fluctuation,transient load/unload,recorded wave analysis,harmonic analysis,testing the static parameter and dynamic parameter

    Applications
    Application

    (1) Control mode: user can choose local control, remote control or intelligent control (PC control)

    (2) Local manual control: local control panel in load bank, with multi load steps, controlled by buttons.

    (3) Remote control: With remote controller box connected to load bank by control cable.

    (4) Intelligent control: user can control load bank by data processing software of PC to make automatic load/unload, display, record and manager the test data, form curve, graph, also can be printed.

    (5) Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.

    (6) Local meter display data: 3 phase voltage, current, active power, reactive power, apparent power, power factor, frequency etc.

    Technical specification
    System Parameters

    Rated Voltage/

    Frequency

    3 phase 4 wire, 440VAC/60Hz,400VAC/50Hz
    MAX Power (AC440V)

    Apparent Power:4375kVA

    Resistive:3500kW

    Inductive:2625kvar

    Steps

    (AC440V)

    Resistive:

    15steps,5,10,10,25,50,100,100,200,200,200,200,400,400,800,800kW

    Inductive:

    15steps,5,10,10,25,25,50,100,100,100,200,200,200,400,400,800kvar


    Note:Below 440V, power based on ohm’s law descending.

    PF0.8
    Precision (each step)±5%
    Precision (Overall)±3%
    Display Precision0.5 class
    Auxiliary Power3 phase 400VAC/50Hz
    Wiring

    Load input——Copper Bar(Star)

    Auxiliary Power——Line Bank

    CommunicationRS485
    InsulationF
    ProtectionIP54
    WorkingContinuity
    CoolingAir cooled,horizontal air intake,vertical air outlet
    Containerpackaging,ladder at the front side, window with mesh
    Transporthoist,lifting eye on the top
    Container ColorGrey (RAL7035)
    Dimension6100mm×2438 mm×2591mm(L×W×H)
    WeightAround 18000KG
    Environment
    Temperature-10℃~+50℃
    RH≤95%
    Altitude≤2500m
    Air Pressure86~106kPa

    Main features

    (1) Communication type: through RS485 communication serial portconnect with PC.

    Also can transform the communication protocol by transverter, then use RS232 or USB to connect.

    (2) Load mode: manual load or automatic load.

    (3) Manual load: input power and power factor, then will load according to the value.

    (4) Preset Load: input the parameter of generator, choice 0%,25%,50%,75%,100%,110%, calculate power value automatically,

    (5) Auto Load: power and time can be set to some stage, process stage test automatically. Allow pause or process next stage during loading.

    (6) Step by Step Load: during steady state load, load bank will increase or reduce power so that smoothly transit into target power, avoiding unscheduled transient load/unload. Step value and step interval can be set.

    (7) Constant Power Load: automatically adjust to the power when the voltage fluctuation, keep the setting value.



    Quality 440 V 3 Phase 4 Wire Reactive Load Bank Constant Power With Dry Load Module for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hebei Kaixiang Electrical Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)