    Brand Name : Kaixiang
    Model Number : AC415V - 271kVA
    Certification : ISO9001
    Price : negotiable
    Payment Terms : Western Union, L/C, T/T
    Supply Ability : 100 Sets / Month
    Delivery Time : Within 30 working days
    • Product Details
    • Company Profile

    Overheating Protection Resistive Load Bank , Automatically Inductive Load Bank

    AC415V - 271kVA Dummy Load Bank In High Performance And Resistive Inductive

    Introduction

    Triumph load can simulate the real working conditions and provides a rigorous test regime for power supplies from 1kW to 60MW. Resistive, inductive(reactive),capacitive or combined load banks can be customised for any application. They can be used for testing numerous sets in a workshop environment, or used for on-site commissioning, witness tests and proof trials.Tailor-made load banks can be supplied for most powers, voltages, frequencies and sizes. Multi-voltage load banks are also available for operation over a large voltage range. At the same time, It can operate in parallel with more than two units.

    Application

    AC415V - 271kVA Dummy Load Bank can be used in a wide variety of applications, such as

    Ups system testing,Battery system testing,Load optimization in prime power applications

    Factory testing of turbines,Factory testing of engine generator sets,To reduce wet stacking problems

    Periodic excercising of stand-by engine generator sets

    Technical specification


    Technical Parameter
    Rating voltage/frequency415VAC power 265kVA; 3 phase 4 wire, 50Hz, phase voltage 240VAC
    Max Load PowerResistive 31kW; inductive 120kvar; capacitive 120kvar
    Load Resolution

    Resistive Load: 10 steps, 0.1, 0.2, 0.2, 0.5 1, 2, 2, 5, 10, 10kW

    Inductive Load: 9 steps, 1, 2, 2, 5, 10, 10, 20, 20, 50kvar

    Capacitive Load: 9 steps, 1, 2, 2, 5, 10, 10, 20, 20, 50kvar

    Power Factor±0.2-1
    Load Tolerance (resistive load)±5%
    Load Tolerance (inductive load)±3%
    Display MeterMultiple function meter
    Fan Control PowerExternal power 380VAC 3 phase 4 wire, 50Hz, phase voltage 220VAC
    Wire Connection

    Load bank input——busbar (star coupling ”Y”)

    Control power input——terminal block

    Communication InterfaceRS232/ RS485
    InsulationF
    Way of WorkingContinuous Working
    CoolingForced air cooling, horizontal inlet air and upwards exhaust cooling
    TransportationHoisting, it has lifting eys in top of case and wheel castors in bottom
    ColorAs customer’s requirements or as our design RAL 7035 gray
    DimensionsAbout 2300*1250*1680mm (L*W*H)
    WeightAbout 1500kgs
    Operating Environment Parameter
    Ambient Temperature-10℃~+40℃
    Relative Humidity≤95%
    Atmospheric Pressure86~106kPa
    Used Placeindoor
    Main features
    Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.

    Overvoltage Protection: the input load voltage is over the safe threshold value, system unload automatically and give an alarm.

    Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.

    Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.

    Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.

    Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.

    Overload protection with fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.

    Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.

    Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.