Sign In | Join Free | My himfr.com
Home > Adjustable Load Bank >

1500 KW 50HZ Reactive Load Bank , Fan Power Portable Resistive Load Bank

Hebei Kaixiang Electrical Technology Co., Ltd
Contact Now
    Buy cheap 1500 KW 50HZ Reactive Load Bank , Fan Power Portable Resistive Load Bank from wholesalers
     
    Buy cheap 1500 KW 50HZ Reactive Load Bank , Fan Power Portable Resistive Load Bank from wholesalers
    • Buy cheap 1500 KW 50HZ Reactive Load Bank , Fan Power Portable Resistive Load Bank from wholesalers
    • Buy cheap 1500 KW 50HZ Reactive Load Bank , Fan Power Portable Resistive Load Bank from wholesalers

    1500 KW 50HZ Reactive Load Bank , Fan Power Portable Resistive Load Bank

    Ask Lasest Price
    Brand Name : Kaixiang
    Model Number : AC480V-1500kW
    Certification : ISO9001
    Price : negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 20 Sets / Month
    Delivery Time : Within 42 working days
    • Product Details
    • Company Profile

    1500 KW 50HZ Reactive Load Bank , Fan Power Portable Resistive Load Bank

    AC480V-1500kW Adjustable Load Bank With 60 HZ And 1900mm * 2900mm * 2100mm

    Introduction

    AC480V-1500kW Adjustable Load Bank can simulate the real working conditions and provides a rigorous test regime for power supplies from 1kW to 60MW. Resistive, inductive(reactive),capacitive or combined load banks can be customised for any application.

    Triumph load are available in stationary type for permanent installation or portable type with fork lift pocket base, castors. Larger load banks, are based on an ISO container construction. Special finishes including custom paint colors and stainless steel casings can be supplied.

    Load banks can be supplied for most powers, voltages, frequencies and sizes. Multi-voltage load banks are also available for operation over a large voltage range. At the same time, It can operate in parallel with more than two units.

    Application

    1. Load optimization in prime power applications

    2. Factory test of turbines

    3. factory test of engine generator sets

    4. To reducewet stacking problems

    5. Periodic excercising of stand-by engine generator sets

    6. Battery system testing

    Technical specification

    Technical Parameters
    Rating Voltage/Frequency480VAC 50Hz/60Hz,3phase 4 wire
    Max Load PowerResistive Load: 1500kW
    Load StepResistive Load:16 steps; 1,2,2,5,10,10,20,50,100,100,200,200,200,200,200,200kW
    Power Factor1
    Load Tolerance(each step)±5%
    Load Tolerance(overall)±3%
    Display Precision0.5 class
    Control Power SupplyExternal 480VAC, 3phase 4wire 50Hz,
    Wire Connection

    Load Power Supply Input——Copper bar (star connection)

    Control power supply input——Connector bar

    Communication InterfaceRS232 and RS485
    Insulation ClassF
    Duty CycleContinuous
    CoolingForced air cooling, horizontal air inlet and air outlet
    TransportationHoisting, there are lifting lug in top of case and wheel castors on the bottom
    Chassis colorGray(RAL7035)
    Size

    Approximately; 1900mm*2900mm*2100mm

    (Width *Length *Height)

    WeightApproximately 2000kg
    Operating Environment Parameter
    Ambient Temperature-10℃~+50℃
    Relative Humidity≤95%
    Altitude≤2500meters
    Atmospheric Pressure86~106kPa
    Main features

    (1) Temperature Display: display real time temperature.

    (2) Measuring meter: display testing data.

    (3) Control mode selector switch: [Local] use panel switch manually operated,and point to [Intelligent] can be operated via PC software. Two methods are mutually exclusive modes of operation; please make sure the current operation mode is in accordance with the corresponding mode.

    (4) Fan Power Supply: push the button, the indicator lights up, fans will work.

    (5) Load Confirm: Master load switch, when the switch is pressed, the yellow indicator lights up, load bank will load/unload according to a preset power loading.

    (6) Emergency stop: In case of emergency, press this switch, immediately stop loading. After resolving the emergency problem, clockwise rotary switch, unlock, continues to load.

    (7) Power setting switch: totally 16 switches:1,2,2,5,10,10,20,50,100,100,200,200,200,200,200,200kW press the corresponding switches, and press the < Load Confirm >.

    (8) Fault: red fault indicator lights up, and with alarm, the load bank will be in protection.

    (9)Emergency Stop Indicator: When load bank under emergency stop locked state, the indicator light and send alarm.

    (10)Overheat Alarm Indicator:When the unit is overheating, the corresponding warning lights up, load bank gives alarm.

    (11)Over-voltage Alarm Indicator:When load bank is under over-voltage protection, the corresponsive light turns on and gives alarm.




    Product Tags:

    lamp load bank

      

    diy load bank

      
    Quality 1500 KW 50HZ Reactive Load Bank , Fan Power Portable Resistive Load Bank for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hebei Kaixiang Electrical Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)