Sign In | Join Free | My himfr.com
Home > 3 Phase Load Bank >

Blue Resistive Reactive Load Bank F Class With Short Circuit Protection

Hebei Kaixiang Electrical Technology Co., Ltd
Contact Now
    Buy cheap Blue Resistive Reactive Load Bank F Class With Short Circuit Protection from wholesalers
     
    Buy cheap Blue Resistive Reactive Load Bank F Class With Short Circuit Protection from wholesalers
    • Buy cheap Blue Resistive Reactive Load Bank F Class With Short Circuit Protection from wholesalers
    • Buy cheap Blue Resistive Reactive Load Bank F Class With Short Circuit Protection from wholesalers

    Blue Resistive Reactive Load Bank F Class With Short Circuit Protection

    Ask Lasest Price
    Brand Name : Kaixiang
    Model Number : AC415V-2500kW
    Certification : ISO9001
    Price : negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 40 Sets per Month
    Delivery Time : Within 30 working days
    • Product Details
    • Company Profile

    Blue Resistive Reactive Load Bank F Class With Short Circuit Protection

    AC415V-2500kW 3 Phase Load Bank With Blue Colour And High Performance

    Product description

    (1) According to the special requirements of users on site, in the agreement the technical standards of AC415V-2500kvA Resistive Inductive Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.

    (2) The system consists of 1 sets of 2500KVA Load Bank, The resistive power is 2000kW, the inductive power is 1500KVAR. The system is made up of two parts of measurement & control and load, mainly including the medium voltage dry type AC load bank, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote control box and PC software and so on.

    Technical Parameter

    System Parameter
    Rating voltage/frequency415V, 3 phase 4 wire 50Hz
    Max Load Power

    Apparent Power: 2500KVA

    Resistive Load: 2000kW

    Inductive Load: 1500KVAR

    Load Resolution

    Resistive Load: 18 steps, 1,2,2,5,10,10,20,50,100,9*200kW

    Inductive Load: 17 steps, 0.75,1,2,2,5,10,10,20,50,100,100,6*200kvar

    When input voltage lower than rated voltage, load power change according to Ohm’ law

    Power Factor0.8(lag)
    Load Tolerance (each step)±5%
    Load Tolerance (overall)±3%
    Fan &Control VoltageExternal AC 3 phase 4 line, 415V/50Hz
    Wire Connection

    Load bank input——Copper bar (star coupling ”Y”)

    Control power input——Connector-bar

    Communication InterfaceRS485,RS232
    InsulationF
    Max Protection GradeIP54
    Duty CycleContinuous
    CoolingForced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
    EnclosureContainer type,with a ladder, air inlet and outlet with mesh enclosure and protection door
    Internal LightingAdequate internal lighting will be provided
    TransportationHoisting, there are lifting lug in top of casing
    ColorGrey RAL7035 or as required
    Dimensions6058mm×2350mm×2591mm(L×W×H)
    Operating Environment Parameter
    WorkplaceOutdoor
    Ambient Temperature-10℃~+50℃
    Relative Humidity≤95%
    Atmospheric Pressure86~106kPa
    Brands of Main Components
    ContactorSchneider
    FuseMiro
    PLCSiemens
    Alloy ResistorKaixiang
    Data Processing SoftwareKaixiang
    Product Advantage

    Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.

    Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.

    Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.

    Overload protection with fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.

    Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.

    Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.

    Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.

    Application

    Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
    Factory testing for generator, static voltage characteristic test, speed characteristic test;
    Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test
    Assist shipyard in mooring test,sea trial test


    Quality Blue Resistive Reactive Load Bank F Class With Short Circuit Protection for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hebei Kaixiang Electrical Technology Co., Ltd
    *Subject:
    *Message: